Smith 1010 Roof Drain Specs & Options

Dimensional data is subject to manufacturing tolerances and change without notice.

Dome height is 8-1/4 in. for the 122.5 sq. in. free area dome and 7-1/4 in. for the 228 sq. in. free area dome. They are regularly furnished in cast iron and not available in polyethylene.

 

Specifications: The Smith 1010 roof drain is used in flat roof construction. Its large profile dome provides sufficient free area for quick rain water drainage while protecting the drain sump and connecting piping from debris. A wide clamping surface holds flashing and roofing materials without puncturing. This drain comes regularly furnished with a Duco cast iron body combined with a flashing clamp and gravel stop, and a polyethylene dome. 

  B (Bottom Outlet) (in.)
Outlet Size (A) Caulk,
No-Hub & Speedi-Set
Threaded C

D

Dia

E

Dia

F

Dia

2 - 4 5 3-3/4 3-3/4* 15-1/4 11 1-1/8
5, 6 5 3-3/4 -- 15-1/4 11 1-1/8
8 (-16) **
10 (-16)**
6 5 -- 16 12-1/2 1-1/8
8, 10
7-3/4 7-3/4 -- 20 16 1-5/8

 

Recommended Deck Openings

Outlet Size (in.) With Sump
Receiver (.in)
Without Sump
Receiver (.in)
2 - 6 in. 17 dia. 14 dia.
8 (-16)**
10 (-16)**
17 dia. 14-3/4 dia.
8 **
10**
21 dia. 18-3/4 dia.

 

* C dimension is to internal stop of Speedi-Set Gasket

** NOTE: 08 & 10 outlet sizes are regularly furnished with a 20 in. dia. flange. If 16 in. dia. flange is required, (-16) MUST be specified. E.g. 1010Y08-16 or 1010Y10-16.

Find and Buy Smith Roof Drains

Outlet Types

  • Caulk Outlet
  • L Speedi-Set Service Weight (2, 3 and 4 in. only)
  • LXH Speedi-Set Extra Heavy (2, 3 and 4 in. only)
  • No-Hub
  • Threaded Outlet

Variations

  • Expansion Joint (specify fig. 1710)
  • Extension (specify height) (-E)
  • "L" Shaped Underdeck Clamp (-CL)
  • Secondary Flashing Clamp (-C2)
  • Sump Receiver (-R)
  • Underdeck Clamp (-C)
  • Vandal Proof Dome (-U)

Optional Materials

  • All Aluminum (-AA)
  • Aluminum Dome (-AD)***
  • Cast Iron Dome (-CID)***
  • Galvanized Cast Iron Dome (-CIDG)***
  • Galvanized Cast Iron Body & Collar (-G)
  • Rough Bronze Dome (-RBD)***
  • Stainless Steel (specify fig. 9780)

***Optional Domes' Free Area

Dome Material 2 - 6 & 8(-16) Outlets 8 & 10 Outlets w/ 20 in. Flange
Aluminum Dome  98 150
Cast Iron Dome  80 --
Bronze Dome 95 150